然后使用联合索引:
| mysql> select uin,id from funkSpeed where uin=10023 and id=162; +------------+----------+ | uin | id | +------------+----------+ | 10023 | 162 | +------------+----------+ 1 row in set (0.00 sec) mysql> explain select uin,id from funkSpeed where uin=10023 and id=162; +-------------+------+---------------+----------+---------+-------------+------+-------------+ | table | type | possible_keys | key | key_len | ref | rows | Extra | +-------------+------+---------------+----------+---------+-------------+------+-------------+ | funkSpeed | ref | uin_id | uin_id | 12 | const,const | 4 | Using index | +-------------+------+---------------+----------+---------+-------------+------+-------------+ 1 row in set (0.00 sec) |
可以看到几乎是秒查,这个时候基本可以断定问题是出现在索引这个地方了
我select的时候次数比较少,每两个select之间id相差10000,所以这里可以忽略掉,而且这里没办法优化,除非在id上面添加索引。
问题发生在update fuckSpeed set type=[type],typeid=[typeid] where id=[id],这里在更新的时候也是会用到查询的,我的mysql版本是5.5,不能explain update,不然肯定可以验证我所说的,这里要更新32w+条数据,每条数据都会去更新,每条数据0.2s左右,这太吓人了~~
解决问题
问题找到了,解决起来就容易多了~~
select的时候加了一个字段uin,改为下面这样select uin,id,url from funkSpeed where id>=101 and id<=200;,然后更新的时候使用update fuckSpeed set type=[type],typeid=[typeid] where uin=[uin] id=[id],这样一来索引就是用上了。
三下五除二改好了代码,试着启动了一个进程,看看效果如何,果然,效果提升的不是一点点,平均30+次/s,这样大概3个小时左右就可以完成所有的更新了。
总结Mysql语句级优化:
1. 性能查的读语句,在innodb中统计行数,建议另外弄一张统计表,采用myisam,定期做统计.一般的对统计的数据不会要求太精准的情况下适用。
2. 尽量不要在数据库中做运算。
3. 避免负向查询和%前缀模糊查询。
4. 不在索引列做运算或者使用函数。
5. 不要在生产环境程序中使用select * from 的形式查询数据。只查询需要使用的列。
6. 查询尽可能使用limit减少返回的行数,减少数据传输时间和带宽浪费。
7. where子句尽可能对查询列使用函数,因为对查询列使用函数用不到索引。
8. 避免隐式类型转换,例如字符型一定要用'',数字型一定不要使用''。
9. 所有的SQL关键词用大写,养成良好的习惯,避免SQL语句重复编译造成系统资源的浪费。